Free shipping
Choice LC E Kit1 Dental Hospital Light Curing Lamp LED Dental Filling Equipment 450-460nm
Checkout Discount 15% Off
At checkout
63.78 AED
75.04 AED
Trendyol's commitments
Easy and free return in 15 days.
Highlighted features:
Choice LC E Kit1 Dental Hospital Light Curing Lamp LED Dental Filling Equipment 450-460nm features
Seller information
Choice LC E Kit1 Dental Hospital Light Curing Lamp LED Dental Filling Equipment 450-460nm reviews
Product details

Additional info
- A maximum of 10 units of this product can be ordered. Trendyol reserves the right to cancel orders over 10 units.
- Barcode No: 3676321380421
Choice LC E Kit1 Dental Hospital Light Curing Lamp LED Dental Filling Equipment 450-460nm features
Safety information
Product description
Color:LC E Kit1
Dental Light Curing Unit
Product Performance
This unit leverages high-power blue LEDs with an output wavelength of 450-460nm as its active light source. It is capable of curing all commercially available dental light-cure composite resins. The device features intelligent microprocessor control, allowing the user to adjust the curing duration as needed. The selected time is clearly displayed on the screen for easy operation.
Product Applications
• Teeth Whitening
• Gum Protection
• Post-Implant Restoration
Technical Parameters
Safety Classification: Class II, Internally Powered, Type B equipment. Non-continuous operation.
Product Name: Light Curing Unit
Model: LA400
Battery: Rechargeable Lithium-ion Battery
Battery Capacity: 2200 mAh
Battery Voltage: 3.7 V DC
Blue Light Wavelength: 450-460 nm
Blue Light Intensity:
High-Intensity Mode: 1500 - 2000 mW/cm2
Pulse/Ramp Mode: 800 - 1500 mW/cm2
Instruction Manual
Press the P button to turn on the device. The indicator light below the current mode will stay on, and the screen will display the operating time for that mode.
Press the M button to switch between different modes.To adjust the time, press and hold the M button for 3 seconds until you hear a beep, then release. The indicator light will blink, indicating that you have entered the time-setting mode. Press M to select a mode, and press P to set the desired operating time. The settings will be confirmed automatically if no further operation is made.
Unplug the device after charging to extend battery life.
If the surface becomes soiled, it can be wiped with alcohol.
Warnings, Cautions & Notes
Allow a cooling interval of more than 40 seconds between consecutive uses.
Do not operate the device while it is connected to the charger.
Never point the light source directly into the eyes. Always install the light shield before commencing the curing procedure to avoid exposure to harmful blue light.
The product surface can be disinfected by wiping with alcohol.
While the device has low magnetic emissions, it is recommended to keep it away from strong magnetic fields to prevent potential interference.
At the end of its service life, this device and its accessories must be disposed of in accordance with local regulations.
The lamp head rotates 360 degrees, allowing the clinician to adjust it for optimal access during procedures.
This product is not impact-resistant. Handle with care during use and avoid dropping it to prevent damage.
This product is intended for use only by qualified healthcare professionals.
Transport and Storage Conditions
Environment:
Temperature Range: -40°C to +55°C
Relative Humidity: < 80%
Transportation: Transportation requirements shall be in accordance with the contract agreement. The product must be protected from rain, snow, and mechanical impact.
Storage: The packaged LED curing unit must be stored indoors in a well-ventilated area, free of corrosive gases. Temperature and humidity conditions must comply with the manufacturer's specifications.