The plaster shaker is a device used by technicians to make plaster models.
Before energizing, adjust the strong and weak switch to the middle 0 position, and select strong vibration or weak vibration after turning on the power.
Place the plaster model to be shaken on the shaker plate Turn on the adjustment knob, adjust it clockwise to increase the oscillation, and adjust it counterclockwise to decrease the oscillation After the shock of the bag model is completed, turn off the knob to stop the shock, and then the model can be removed for use.
Precautions: The power supply used by the oscillator is reliably grounded, and the knob is adjusted when it is oscillating.
It should not be too fast, but slowly increase from small to large or slowly from large to small, and often scrub the surface of the body to extend the service life.
Trouble phenomenon: Vibration and noise suddenly increase during work, accompanied by abnormal sound.
Cause analysis: The gap between the vibrating platform and the transformer is abnormal.
Troubleshooting: Cut off the power supply, peel off the rubber platform, turn the device upside down, and use a Phillips screwdriver to remove 4 M6 screws to separate the vibration platform from the main body.
Check one by one whether the four vibrating columns are loose or have different heights.
Adjust the height to 68mm as appropriate and lock the four columns.
(Adjustment tool: 10mm opposite side hexagon socket wrench)